Xycd60 Manual __top__ Info
for about 3 seconds to enter the parameter setting interface. Short press SET to cycle through the parameters: UP : Upper limit voltage. dn : Lower limit voltage. OP : Conduction time (00:00 to 99:59, or "----" to disable). dOP : Delayed conduction time (0–999 seconds). FOP : Forced start time (0–10 seconds) in discharge mode. Use UP/DOWN buttons to adjust the values. Press and hold SET again to save and exit. Voltage Percentage Calculation
If OP is set, the relay will automatically disconnect after the specified duration, even if the voltage threshold hasn't been reached. This acts as a safety backup. xycd60 manual
Percentage=Current Voltage−dnUP−dn×100%Percentage equals the fraction with numerator Current Voltage minus dn and denominator UP minus dn end-fraction cross 100 % for about 3 seconds to enter the parameter setting interface
The XY-CD60 acts as a programmable voltage-controlled switch. It does not provide power itself; rather, it controls an onboard relay to connect or disconnect a power source (for charging) or a load (for discharging) based on voltage thresholds you define. Voltage Range: DC 6V–60V. OP : Conduction time (00:00 to 99:59, or "----" to disable)
The module calculates the battery percentage using the formula: